Dreame L10s Ultra SE (Special Edition) now available for purchase

With the Dreame L10s Ultra, it already offered all the key features for a high-end robot vacuum – mop & vacuum, auto empty, mop cleaning, auto water refilling, AI+3D navigation, and more. It provided an automated cleaning experience. Well, almost all except that you have to remove the refill and clear the water tanks. The new Dreame L10s Ultra SE addresses this manual step involving the water tanks, making it even more automated than it already is.

What’s new with the Special Edition (SE)?

Dreame L10s Ultra SE is pretty much exactly the same as the Dreame L10s Ultra, just that it adds the Water Hookup Kit – for auto refilling and drainage of water. This is the dream for all the lazy people out there. With the Dreame L10s Ultra SE, you would only have to remember to clear out the dust bag every now and then.

L10s UltraL10s Ultra SE
NavigationLDSLDS
Obstacle avoidanceLDS + 3D structured light + AI action + mechanical bumpersLDS + 3D structured light + AI action + mechanical bumpers
Suction power (Pa)5,3005,300
Built-in water tankAutomatic water refillAutomatic water refill
Vacuuming & Mopping solutionBristleless rubber brush + Dual rotary mopsBristleless rubber brush + Dual rotary mops
Mop RaisingYes (max 7mm)Yes (max 7mm)
Base station functionalityAuto-empty + Mops self-cleaningAuto-empty + Mops self-cleaning
Mop drying solutionHot air drying (2 hours)Hot air drying (2 hours)
Dust bag volume (L)33
Automatic detergent addingYesYes
Remote video supervisionYesYes
Water hookup kitNoYes

Installation checklist

However, convenience does not come that easily. You’d have to ensure that you have all the conditions met below before you can install the Dreame L10s Ultra SE for auto refilling and drainage of water.

Water supply checks

If you satisfy the above conditions, you then have to check if your home has the hardware and setup for installation as you need both supply and drainage.

Supply of clean water

  1. Water pressure is between 0.14 MPa – 1.0 MPa
  2. G1/2 3-way diverter valve can be installed
  3. Hot water cannot be used

Drainage of used water

Drainage waysRequirements
Wall pipeThe used water outlet of the base station is about 40cm from the ground, and the outlet of the wall pipe shall not be higher than it.
Floor drainIf the end of the used water pipe is a floor drain, it must be matched with the diameter of the used water pipe.
Floor drain pipeThe height of the ground drain pipe is recommended to be 15cm.
PVC conduit + Floor drainIf the end of the used water pipe is a floor drain, it is recommended that the height of the PVC conduit be 10-20cm from the ground.
PVC conduit + Floor drain pipeThe PVC conduit should be less than 30cm from the ground, and 15cm is recommended.

Installation steps

You can refer to the below steps for installation of the Dreame L10s Ultra SE.

Testing the device

The app provides a useful feature to test if the installation is successfully. If the Water Hookup Kit is installed successfully, you will see the following screen in the app below:

Where to buy

If your house has the ability to support the water supply and drainage for the Dreame L10s Ultra SE, it is a great alternative to consider over the Dreame L10s Ultra as the convenience of auto-refilling the water tank and auto-draining the dirty water will surely elevate your quality of life.

  • Auto sweep
  • Auto mop
  • Auto empty
  • Self-cleaning
  • Mop drying
  • Auto water refill and drainage (new to Dreame L10s Ultra SE)

You can visit Dreame’s official website to find out more about the new L10s Ultra SE robot vacuum.